Hi,
In the error, I see the message "Unable to open data specification WISH_GIC_PROD_TS_28a1728d_1680601898661".
Inside the FS environment location (/ie01/ForecastStudio/) you should have multiple folders for Project, Data specification, etc. like the following:
Can you check permission issues for both Projects & DataSpecicications folders? To know the exact folders, you can open the file "/ie01/ForecastStudio/DataSpecifications/WISH_GIC_PROD_TS_28a1728d_1680601898661/libraries_declaration.sas" which should have lines similar to the following:
%let HPF_PROJECTDIR = /ie01/ForecastStudio/Projects/CC_DCC_gic_prod;
%let HPF_DATASPECDIR = /ie01/ForecastStudio/DataSpecifications/WISH_GIC_PROD_TS_28a1728d_1680601898661/;
Copy the above paths for Project & Data specification. Manually provide recursive permissions 775 or 777 to both those locations.
chmod -R 775 /ie01/ForecastStudio/Projects/CC_DCC_gic_prod/
chmod -R 775 /ie01/ForecastStudio/DataSpecifications/WISH_GIC_PROD_TS_28a1728d_1680601898661/
Once the permission settings are changed, try to run the failing %FSLOAD macro to see if that works.