Why RFSTDTC, RFXTSDTC , RFENDTC and RFXENDTC are called record qualifiers in DM whereas __STDTC variables in other domains are called as timing variables?
To get a more accurate and complete answer, I'd suggest asking the SDS team at CDISC.
I will take a stab at answering, but my answer doesn't feel particularly fulfilling even to me. Unlike the --STDTC variables where the -- takes on the domain id, the DM domain's Subject Reference Start Date/Time uses RF and not DM as the prefix. I can't give you a justification over the difference, but there is one. Interestingly, in the 3.1.1 STDMIG the DM RFSTDTC variable was classified as Timing as were the other --STDTC patterned domain variables like CMSTDTC.
Best regards,
Bill
RFSTDTC, RFENDTC, RFXSTDTC, RFXENDTC, RFICDTC, RFPENDTC and BRTHDTC represent date/time values, but they are considered to have
a Record Qualifier role in DM. They are not considered to be Timing Variables because they are not intended for use in the ge neral observation classes.
Don't miss out on SAS Innovate - Register now for the FREE Livestream!
Can't make it to Vegas? No problem! Watch our general sessions LIVE or on-demand starting April 17th. Hear from SAS execs, best-selling author Adam Grant, Hot Ones host Sean Evans, top tech journalist Kara Swisher, AI expert Cassie Kozyrkov, and the mind-blowing dance crew iLuminate! Plus, get access to over 20 breakout sessions.