    <description>&lt;P&gt;Is this only a problem when the table is autoloaded? In other words, can you manually load the 4GB table using Visual Analytics Administrator?&lt;/P&gt;
&lt;P&gt;&lt;BR /&gt;If the problem is only autoload, you might neet to set MEMSIZE 0 in the config file specifically for autoload.&amp;nbsp;&lt;BR /&gt;&lt;A href="https://go.documentation.sas.com/doc/en/bicdc/9.4/vaag/n0nm6qjzfz4eban1237qqrcmxz0j.htm#n1837d572wne1xn1rha88n17apiw" target="_blank"&gt;https://go.documentation.sas.com/doc/en/bicdc/9.4/vaag/n0nm6qjzfz4eban1237qqrcmxz0j.htm#n1837d572wne1xn1rha88n17apiw&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
    <pubDate>Tue, 01 Feb 2022 18:42:54 GMT</pubDate>
    <dc:creator>Madelyn_SAS</dc:creator>
    <dc:date>2022-02-01T18:42:54Z</dc:date>
    <item>
      <title>SAS VA Autoload insufficient memory error for large tables</title>
      <link>https://communities.sas.com/t5/SAS-Visual-Analytics/SAS-VA-Autoload-insufficient-memory-error-for-large-tables/m-p/782288#M15662</link>
      <description>&lt;P&gt;We are using SAS VA 7.5 (non-distributed) and have autoload in place to load the table on Linux. Smaller tables are loading fine vs large tables having "Insufficient resources to perform the operation" + "sas system stopped processing this step because of insufficient memory" error.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;SAS VA Linux machine has total of 94 gb RAM&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;workspaceserver_usermods.sh for SASAppVA server has&amp;nbsp;&lt;/P&gt;
&lt;P&gt;USERMODS_OPTIONS="-memsize 0 -cpucount ACTUAL"&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;va.AuditingEnabled is "false" for Visual Analytics 7.5 definition underneath "SAS Application Infrastructure" Advance settings.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;From autoload job log,&amp;nbsp;&lt;/P&gt;
&lt;P&gt;When it complains about insufficient resource for ~4 gb table, details is as below,&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;real time 5.71 sec&lt;/P&gt;
&lt;P&gt;user cpu time 1.51 sec&lt;/P&gt;
&lt;P&gt;system cpu time .59 sec&lt;/P&gt;
&lt;P&gt;memory 6266.09k&lt;/P&gt;
&lt;P&gt;OS memory 20648.00k&lt;/P&gt;
&lt;P&gt;page fault 0&lt;/P&gt;
&lt;P&gt;page reclaims 2903&lt;/P&gt;
&lt;P&gt;page swaps 0&lt;/P&gt;
&lt;P&gt;Vol. context switches 1133&lt;/P&gt;
&lt;P&gt;Invol. context switches 1&amp;nbsp;&lt;/P&gt;
&lt;P&gt;block input operations 0&lt;/P&gt;
&lt;P&gt;block output operations 240&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 24 Nov 2021 19:13:35 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Visual-Analytics/SAS-VA-Autoload-insufficient-memory-error-for-large-tables/m-p/782288#M15662</guid>
      <dc:creator>woo</dc:creator>
      <dc:date>2021-11-24T19:13:35Z</dc:date>
    </item>
    <item>
      <title>Re: SAS VA Autoload insufficient memory error for large tables</title>
      <link>https://communities.sas.com/t5/SAS-Visual-Analytics/SAS-VA-Autoload-insufficient-memory-error-for-large-tables/m-p/793864#M15790</link>
      <description>&lt;P&gt;Is this only a problem when the table is autoloaded? In other words, can you manually load the 4GB table using Visual Analytics Administrator?&lt;/P&gt;
&lt;P&gt;&lt;BR /&gt;If the problem is only autoload, you might neet to set MEMSIZE 0 in the config file specifically for autoload.&amp;nbsp;&lt;BR /&gt;&lt;A href="https://go.documentation.sas.com/doc/en/bicdc/9.4/vaag/n0nm6qjzfz4eban1237qqrcmxz0j.htm#n1837d572wne1xn1rha88n17apiw" target="_blank"&gt;https://go.documentation.sas.com/doc/en/bicdc/9.4/vaag/n0nm6qjzfz4eban1237qqrcmxz0j.htm#n1837d572wne1xn1rha88n17apiw&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 01 Feb 2022 18:42:54 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Visual-Analytics/SAS-VA-Autoload-insufficient-memory-error-for-large-tables/m-p/793864#M15790</guid>
      <dc:creator>Madelyn_SAS</dc:creator>
      <dc:date>2022-02-01T18:42:54Z</dc:date>
    </item>
  </channel>
</rss>
