    <description>Hello,&lt;BR /&gt;
&lt;BR /&gt;
First of all, i don't know what forum i have to write this question. It's seem that doesn't fit to anyone.&lt;BR /&gt;
My problem is when i'm running the application i press enter for processing some task but the execution stop waiting for key press to continue.&lt;BR /&gt;
The enviroment is:&lt;BR /&gt;
i have an aplication with sas/af working with main frame, i call this aplication with the command&lt;BR /&gt;
DM 'AF C=FUENTES.EAES2009.EAES0050.PROGRAM AUTOSAVE=Y' AF CONTINUE;     &lt;BR /&gt;
I have a menu, that is a program, with control enter, and if fields are ok, then i call an scl to process scl code and some submit continue (no control enter or somthing like that). Then i invoke a program (with control enter) to ask if the user want to continue with the execution.&lt;BR /&gt;
The flow it's this:&lt;BR /&gt;
Program -&amp;gt; SCL with submit continue -&amp;gt; SCL continue/cancel&lt;BR /&gt;
 &lt;BR /&gt;
Some ideas to start to delimitate the problem?&lt;BR /&gt;
&lt;BR /&gt;
Thank you a lot.</description>
    <pubDate>Wed, 07 Jul 2010 07:46:03 GMT</pubDate>
    <dc:creator>deleted_user</dc:creator>
    <dc:date>2010-07-07T07:46:03Z</dc:date>
    <item>
      <title>Sas/AF and submit continue, scl waits for user intervention</title>
      <link>https://communities.sas.com/t5/SAS-Enterprise-Guide/Sas-AF-and-submit-continue-scl-waits-for-user-intervention/m-p/44940#M5174</link>
      <description>Hello,&lt;BR /&gt;
&lt;BR /&gt;
First of all, i don't know what forum i have to write this question. It's seem that doesn't fit to anyone.&lt;BR /&gt;
My problem is when i'm running the application i press enter for processing some task but the execution stop waiting for key press to continue.&lt;BR /&gt;
The enviroment is:&lt;BR /&gt;
i have an aplication with sas/af working with main frame, i call this aplication with the command&lt;BR /&gt;
DM 'AF C=FUENTES.EAES2009.EAES0050.PROGRAM AUTOSAVE=Y' AF CONTINUE;     &lt;BR /&gt;
I have a menu, that is a program, with control enter, and if fields are ok, then i call an scl to process scl code and some submit continue (no control enter or somthing like that). Then i invoke a program (with control enter) to ask if the user want to continue with the execution.&lt;BR /&gt;
The flow it's this:&lt;BR /&gt;
Program -&amp;gt; SCL with submit continue -&amp;gt; SCL continue/cancel&lt;BR /&gt;
 &lt;BR /&gt;
Some ideas to start to delimitate the problem?&lt;BR /&gt;
&lt;BR /&gt;
Thank you a lot.</description>
      <pubDate>Wed, 07 Jul 2010 07:46:03 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Enterprise-Guide/Sas-AF-and-submit-continue-scl-waits-for-user-intervention/m-p/44940#M5174</guid>
      <dc:creator>deleted_user</dc:creator>
      <dc:date>2010-07-07T07:46:03Z</dc:date>
    </item>
    <item>
      <title>Re: Sas/AF and submit continue, scl waits for user intervention</title>
      <link>https://communities.sas.com/t5/SAS-Enterprise-Guide/Sas-AF-and-submit-continue-scl-waits-for-user-intervention/m-p/44941#M5175</link>
      <description>Hi:&lt;BR /&gt;
  There isn't a specific forum for SAS/AF questions. The EG forum is probably not the best forum to work with for this question. &lt;BR /&gt;
&lt;BR /&gt;
  Your best resource for SAS/AF and SCL questions will be SAS Tech Support -- for one thing, the version of SAS that you're using will make a difference here, as there have been some modifications to SCL in different versions of SAS. For another thing, the DM invocation command is not so important as your source code.&lt;BR /&gt;
 &lt;BR /&gt;
  To open a track with Tech Support, go to:&lt;BR /&gt;
&lt;A href="http://support.sas.com/ctx/supportform/createForm" target="_blank"&gt;http://support.sas.com/ctx/supportform/createForm&lt;/A&gt;&lt;BR /&gt;
 &lt;BR /&gt;
cynthia</description>
      <pubDate>Wed, 07 Jul 2010 15:10:57 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Enterprise-Guide/Sas-AF-and-submit-continue-scl-waits-for-user-intervention/m-p/44941#M5175</guid>
      <dc:creator>Cynthia_sas</dc:creator>
      <dc:date>2010-07-07T15:10:57Z</dc:date>
    </item>
    <item>
      <title>Re: Sas/AF and submit continue, scl waits for user intervention</title>
      <link>https://communities.sas.com/t5/SAS-Enterprise-Guide/Sas-AF-and-submit-continue-scl-waits-for-user-intervention/m-p/44942#M5176</link>
      <description>Thank you a lot Cynthia, i was trying to avoid contacting with tech support but it's seems not a common problem.</description>
      <pubDate>Thu, 08 Jul 2010 10:05:56 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Enterprise-Guide/Sas-AF-and-submit-continue-scl-waits-for-user-intervention/m-p/44942#M5176</guid>
      <dc:creator>deleted_user</dc:creator>
      <dc:date>2010-07-08T10:05:56Z</dc:date>