<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg in SAS Programming</title>
    <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902822#M356795</link>
    <description>&lt;P&gt;Please show us the LOG too. Copy the log as text and paste it into the window that appears when you click on the &amp;lt;/&amp;gt; icon.&lt;/P&gt;
&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="PaigeMiller_0-1663012019648.png" style="width: 859px;"&gt;&lt;img src="https://communities.sas.com/t5/image/serverpage/image-id/75161i0E71B1489A6C9839/image-size/large?v=v2&amp;amp;px=999" role="button" title="PaigeMiller_0-1663012019648.png" alt="PaigeMiller_0-1663012019648.png" /&gt;&lt;/span&gt;&lt;/P&gt;</description>
    <pubDate>Mon, 13 Nov 2023 18:17:09 GMT</pubDate>
    <dc:creator>PaigeMiller</dc:creator>
    <dc:date>2023-11-13T18:17:09Z</dc:date>
    <item>
      <title>How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902813#M356788</link>
      <description>&lt;P&gt;WARNING: Most ODS graphics with more than 5000 points have been suppressed. Use the&lt;BR /&gt;PLOTS(MAXPOINTS= ) option in the PROC REG statement to change or override the cutoff.&lt;/P&gt;&lt;P&gt;SAS version: 9.4 (TSI m6)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I received the warning message above after running Proc Reg. Then, I was not allowed to resubmit the SAS file.&amp;nbsp;&lt;/P&gt;&lt;P&gt;Thus, I closed and reopened the SAS program to resubmit the file for the outputs.&lt;/P&gt;&lt;P&gt;Alternatively, I submitted Proc Reg with PLOTS(MAXPOINTS=NONE). The warning message is no longer available in the log file.&lt;/P&gt;&lt;P&gt;Nonetheless, the result is the same. I should close and reopen the SAS program for another run of the SAS file.&lt;/P&gt;&lt;P&gt;Any comments will be appreciated.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 17:43:54 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902813#M356788</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T17:43:54Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902816#M356791</link>
      <description>&lt;P&gt;What ODS graphics are you trying to produce?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;SHOW US your code.&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 17:54:52 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902816#M356791</guid>
      <dc:creator>PaigeMiller</dc:creator>
      <dc:date>2023-11-13T17:54:52Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902820#M356793</link>
      <description>&lt;P&gt;Related SAS code.&lt;/P&gt;&lt;P&gt;proc reg data=out1p PLOTS(MAXPOINTS=NONE) ;&lt;BR /&gt;model prcc_f = sale_p ;&lt;BR /&gt;run;&lt;BR /&gt;proc reg data=out1n ;&lt;BR /&gt;model prcc_f = sale_p ;&lt;BR /&gt;run;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 18:11:23 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902820#M356793</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T18:11:23Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902822#M356795</link>
      <description>&lt;P&gt;Please show us the LOG too. Copy the log as text and paste it into the window that appears when you click on the &amp;lt;/&amp;gt; icon.&lt;/P&gt;
&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="PaigeMiller_0-1663012019648.png" style="width: 859px;"&gt;&lt;img src="https://communities.sas.com/t5/image/serverpage/image-id/75161i0E71B1489A6C9839/image-size/large?v=v2&amp;amp;px=999" role="button" title="PaigeMiller_0-1663012019648.png" alt="PaigeMiller_0-1663012019648.png" /&gt;&lt;/span&gt;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 18:17:09 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902822#M356795</guid>
      <dc:creator>PaigeMiller</dc:creator>
      <dc:date>2023-11-13T18:17:09Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902825#M356798</link>
      <description>&lt;P&gt;NOTE: Copyright (c) 2016 by SAS Institute Inc., Cary, NC, USA.&lt;BR /&gt;NOTE: SAS (r) Proprietary Software 9.4 (TS1M6)&lt;BR /&gt;Licensed to TEXAS A&amp;amp;M UNIVERSITY - SFA T&amp;amp;R, Site 70080787.&lt;BR /&gt;NOTE: This session is executing on the X64_10HOME platform.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;NOTE: Analytical products:&lt;/P&gt;&lt;P&gt;SAS/STAT 15.1&lt;BR /&gt;SAS/ETS 15.1&lt;BR /&gt;SAS/OR 15.1&lt;BR /&gt;SAS/IML 15.1&lt;BR /&gt;SAS/QC 15.1&lt;/P&gt;&lt;P&gt;NOTE: Additional host information:&lt;/P&gt;&lt;P&gt;X64_10HOME WIN 10.0.19041 Workstation&lt;/P&gt;&lt;P&gt;NOTE: SAS initialization used:&lt;BR /&gt;real time 1.53 seconds&lt;BR /&gt;cpu time 1.09 seconds&lt;/P&gt;&lt;P&gt;1 options nocenter errors=1M;&lt;BR /&gt;2 OPTIONS nomacrogen NoSymbolgen nomlogic nomprint nomfile;&lt;BR /&gt;&lt;BR /&gt;5 libname cn 'c://users/brian/desktop/valuation_sales';&lt;BR /&gt;NOTE: Libref CN was successfully assigned as follows:&lt;BR /&gt;Engine: V9&lt;BR /&gt;Physical Name: c:\\users\brian\desktop\valuation_sales&lt;BR /&gt;6 *proc contents data=cn.ben_all_new;&lt;BR /&gt;&lt;BR /&gt;9 data out1n out1p; set cn.variables;&lt;BR /&gt;10 seq_p=seq/csho;&lt;BR /&gt;11 sale_p=sale/csho;&lt;BR /&gt;12 salec_p=(sale-sale_l)/csho;&lt;BR /&gt;13&lt;BR /&gt;14 *if de gt 1;&lt;BR /&gt;15&lt;BR /&gt;16 if epspi lt 0 then neg=0;&lt;BR /&gt;17 else neg=1;&lt;BR /&gt;18 if neg=0 then output out1n;&lt;BR /&gt;19 else output out1p;&lt;BR /&gt;20 run;&lt;/P&gt;&lt;P&gt;NOTE: There were 147951 observations read from the data set CN.VARIABLES.&lt;BR /&gt;NOTE: The data set WORK.OUT1N has 68955 observations and 49 variables.&lt;BR /&gt;NOTE: The data set WORK.OUT1P has 78996 observations and 49 variables.&lt;BR /&gt;NOTE: DATA statement used (Total process time):&lt;BR /&gt;real time 0.07 seconds&lt;BR /&gt;cpu time 0.07 seconds&lt;/P&gt;&lt;P&gt;&lt;BR /&gt;21&lt;BR /&gt;22 proc reg data=out1p PLOTS(MAXPOINTS=NONE) ;&lt;BR /&gt;NOTE: Writing HTML Body file: sashtml.htm&lt;BR /&gt;23 model prcc_f = sale_p ;&lt;BR /&gt;24 run;&lt;/P&gt;&lt;P&gt;&lt;BR /&gt;NOTE: PROCEDURE REG used (Total process time):&lt;BR /&gt;real time 13.75 seconds&lt;BR /&gt;cpu time 2.61 seconds&lt;/P&gt;&lt;P&gt;&lt;BR /&gt;25 proc reg data=out1n ;&lt;BR /&gt;26 model prcc_f = sale_p ;&lt;BR /&gt;27 run;&lt;/P&gt;&lt;P&gt;WARNING: Most ODS graphics with more than 5000 points have been suppressed. Use the&lt;BR /&gt;PLOTS(MAXPOINTS= ) option in the PROC REG statement to change or override the cutoff.&lt;BR /&gt;NOTE: Heat maps are displayed instead of scatter plots when residual plots or fit plots are&lt;BR /&gt;produced.&lt;BR /&gt;28 *proc print data=out1n (obs=50);&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 18:23:55 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902825#M356798</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T18:23:55Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902828#M356800</link>
      <description>&lt;P&gt;Hello Diamond,&lt;/P&gt;&lt;P&gt;Thanks for your interest in my post.&amp;nbsp;&lt;/P&gt;&lt;P&gt;I have posted the SAS code and log files.&lt;/P&gt;&lt;P&gt;In addition, I renewed the SAS site license for 2024 recently.&amp;nbsp;&lt;/P&gt;&lt;P&gt;Then, I have experienced the error.&amp;nbsp;&lt;/P&gt;&lt;P&gt;Many thanks.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 18:31:09 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902828#M356800</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T18:31:09Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902830#M356801</link>
      <description>&lt;P&gt;Repeating:&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Copy the log as text and paste it into the window that appears when you click on the &amp;lt;/&amp;gt; icon.&lt;/P&gt;
&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="PaigeMiller_0-1699900743276.png" style="width: 400px;"&gt;&lt;img src="https://communities.sas.com/t5/image/serverpage/image-id/89703i797B759183DE7484/image-size/medium?v=v2&amp;amp;px=400" role="button" title="PaigeMiller_0-1699900743276.png" alt="PaigeMiller_0-1699900743276.png" /&gt;&lt;/span&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 18:39:15 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902830#M356801</guid>
      <dc:creator>PaigeMiller</dc:creator>
      <dc:date>2023-11-13T18:39:15Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902831#M356802</link>
      <description>NOTE: Copyright (c) 2016 by SAS Institute Inc., Cary, NC, USA.&lt;BR /&gt;NOTE: SAS (r) Proprietary Software 9.4 (TS1M6)&lt;BR /&gt;Licensed to TEXAS A&amp;amp;M UNIVERSITY - SFA T&amp;amp;R, Site 70080787.&lt;BR /&gt;NOTE: This session is executing on the X64_10HOME platform.&lt;BR /&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;BR /&gt;NOTE: Analytical products:&lt;BR /&gt;&lt;BR /&gt;SAS/STAT 15.1&lt;BR /&gt;SAS/ETS 15.1&lt;BR /&gt;SAS/OR 15.1&lt;BR /&gt;SAS/IML 15.1&lt;BR /&gt;SAS/QC 15.1&lt;BR /&gt;&lt;BR /&gt;NOTE: Additional host information:&lt;BR /&gt;&lt;BR /&gt;X64_10HOME WIN 10.0.19041 Workstation&lt;BR /&gt;&lt;BR /&gt;NOTE: SAS initialization used:&lt;BR /&gt;real time 1.53 seconds&lt;BR /&gt;cpu time 1.09 seconds&lt;BR /&gt;&lt;BR /&gt;1 options nocenter errors=1M;&lt;BR /&gt;2 OPTIONS nomacrogen NoSymbolgen nomlogic nomprint nomfile;&lt;BR /&gt;&lt;BR /&gt;5 libname cn 'c://users/brian/desktop/valuation_sales';&lt;BR /&gt;NOTE: Libref CN was successfully assigned as follows:&lt;BR /&gt;Engine: V9&lt;BR /&gt;Physical Name: c:\\users\brian\desktop\valuation_sales&lt;BR /&gt;6 *proc contents data=cn.ben_all_new;&lt;BR /&gt;&lt;BR /&gt;9 data out1n out1p; set cn.variables;&lt;BR /&gt;10 seq_p=seq/csho;&lt;BR /&gt;11 sale_p=sale/csho;&lt;BR /&gt;12 salec_p=(sale-sale_l)/csho;&lt;BR /&gt;13&lt;BR /&gt;14 *if de gt 1;&lt;BR /&gt;15&lt;BR /&gt;16 if epspi lt 0 then neg=0;&lt;BR /&gt;17 else neg=1;&lt;BR /&gt;18 if neg=0 then output out1n;&lt;BR /&gt;19 else output out1p;&lt;BR /&gt;20 run;&lt;BR /&gt;&lt;BR /&gt;NOTE: There were 147951 observations read from the data set CN.VARIABLES.&lt;BR /&gt;NOTE: The data set WORK.OUT1N has 68955 observations and 49 variables.&lt;BR /&gt;NOTE: The data set WORK.OUT1P has 78996 observations and 49 variables.&lt;BR /&gt;NOTE: DATA statement used (Total process time):&lt;BR /&gt;real time 0.07 seconds&lt;BR /&gt;cpu time 0.07 seconds&lt;BR /&gt;&lt;BR /&gt;&lt;BR /&gt;21&lt;BR /&gt;22 proc reg data=out1p PLOTS(MAXPOINTS=NONE) ;&lt;BR /&gt;NOTE: Writing HTML Body file: sashtml.htm&lt;BR /&gt;23 model prcc_f = sale_p ;&lt;BR /&gt;24 run;&lt;BR /&gt;&lt;BR /&gt;&lt;BR /&gt;NOTE: PROCEDURE REG used (Total process time):&lt;BR /&gt;real time 13.75 seconds&lt;BR /&gt;cpu time 2.61 seconds&lt;BR /&gt;&lt;BR /&gt;&lt;BR /&gt;25 proc reg data=out1n ;&lt;BR /&gt;26 model prcc_f = sale_p ;&lt;BR /&gt;27 run;&lt;BR /&gt;&lt;BR /&gt;WARNING: Most ODS graphics with more than 5000 points have been suppressed. Use the&lt;BR /&gt;PLOTS(MAXPOINTS= ) option in the PROC REG statement to change or override the cutoff.&lt;BR /&gt;NOTE: Heat maps are displayed instead of scatter plots when residual plots or fit plots are&lt;BR /&gt;produced.&lt;BR /&gt;28 *proc print data=out1n (obs=50);</description>
      <pubDate>Mon, 13 Nov 2023 18:44:34 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902831#M356802</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T18:44:34Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902832#M356803</link>
      <description>I am not allowed to paste the text in the window as suggested. Thus, I am sending the log file in the reply. Otherwise, the additional guidance will be appreciated.</description>
      <pubDate>Mon, 13 Nov 2023 18:48:24 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902832#M356803</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T18:48:24Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902833#M356804</link>
      <description>&lt;P&gt;Ok&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I don't understand why MAXPOINTS=NONE doesn't do what the documentation says it does, maybe it is poorly written, or we are understanding it incorrectly. Try MAXPOINTS=80000&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 18:57:21 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902833#M356804</guid>
      <dc:creator>PaigeMiller</dc:creator>
      <dc:date>2023-11-13T18:57:21Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902852#M356807</link>
      <description>&lt;P&gt;Thanks for the suggestion, Diamond.&lt;/P&gt;&lt;P&gt;The outputs (maxpoints=80000) include the plots (graphics) I do not need. However, I am not allowed to rerun the SAS file.&lt;/P&gt;&lt;P&gt;Thus, I have to close the SAS program and submit the SAS file after reopening the SAS program.&lt;/P&gt;&lt;P&gt;Let us wait for other suggestions.&lt;/P&gt;&lt;P&gt;Again, many thanks.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 20:23:34 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902852#M356807</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T20:23:34Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902855#M356809</link>
      <description>&lt;BLOCKQUOTE&gt;&lt;HR /&gt;&lt;a href="https://communities.sas.com/t5/user/viewprofilepage/user-id/460015"&gt;@Brlee&lt;/a&gt;&amp;nbsp;wrote:&lt;BR /&gt;
&lt;P&gt;Thanks for the suggestion, Diamond.&lt;/P&gt;
&lt;P&gt;The outputs (maxpoints=80000) include the plots (graphics) I do not need. However, I am not allowed to rerun the SAS file.&lt;/P&gt;
&lt;P&gt;Thus, I have to close the SAS program and submit the SAS file after reopening the SAS program.&lt;/P&gt;
&lt;P&gt;Let us wait for other suggestions.&lt;/P&gt;
&lt;P&gt;Again, many thanks.&amp;nbsp;&lt;/P&gt;
&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;
&lt;P&gt;Please re-read the above post and edit it for clarity.&lt;/P&gt;
&lt;P&gt;You say you are " not allowed to rerun the SAS file" but go onto to say close the Sas program and submit the file. that sure sounds like 'rerunning' the "file".&lt;/P&gt;
&lt;P&gt;I don't see a clear description of what you are attempting to solve. Just clean up the log? Or create a specific plot?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I suggest that you read the online help in the Details section about "Interactive Analysis". I suspect that your "not allowed" is because you are not actually ending proc reg correctly and something thinks you are intending interactive analysis.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;If you submit code like this:&lt;/P&gt;
&lt;PRE&gt;Proc reg data=sashelp.class;
   var weight height;
   model weight=age;
   run;&lt;/PRE&gt;
&lt;P&gt;while the output in results is displayed you might, depending on your operating environment see in the margin of the editor a note&amp;nbsp; "Proc Reg is running".&lt;/P&gt;
&lt;P&gt;Proc Reg is one of the procedures that allows significant interaction while running and the procedure does not end until you submit a QUIT; statement.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 13 Nov 2023 20:37:50 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902855#M356809</guid>
      <dc:creator>ballardw</dc:creator>
      <dc:date>2023-11-13T20:37:50Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902866#M356815</link>
      <description>Hello Ballardw,&lt;BR /&gt;The quick statement solves my issue. As an occasional SAS user, I have forgotten "Quit." Many thanks for your SUPER comment.</description>
      <pubDate>Mon, 13 Nov 2023 21:53:33 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902866#M356815</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T21:53:33Z</dc:date>
    </item>
    <item>
      <title>Re: How do I respond to the warning message, PLOTS(MAXPOINTS=) in the log file of Proc Reg</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902870#M356817</link>
      <description>Many thanks, again.</description>
      <pubDate>Mon, 13 Nov 2023 21:57:03 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-do-I-respond-to-the-warning-message-PLOTS-MAXPOINTS-in-the/m-p/902870#M356817</guid>
      <dc:creator>Brlee</dc:creator>
      <dc:date>2023-11-13T21:57:03Z</dc:date>
    </item>
  </channel>
</rss>
