<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: How to apply multiple set property using proc sql? in SAS Programming</title>
    <link>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156683#M30601</link>
    <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;To re-write an old favourite - select needle from haystack&lt;/P&gt;&lt;P&gt;How about - insert screw into wood&lt;/P&gt;&lt;P&gt;What could be simpler?&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
    <pubDate>Fri, 06 Feb 2015 14:10:45 GMT</pubDate>
    <dc:creator>RW9</dc:creator>
    <dc:date>2015-02-06T14:10:45Z</dc:date>
    <item>
      <title>How to apply multiple set property using proc sql?</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156679#M30597</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Input -&lt;/P&gt;&lt;P&gt;I have two datasets -&lt;/P&gt;&lt;P&gt;Data Tab1;&lt;/P&gt;&lt;P&gt;input id x $;&lt;/P&gt;&lt;P&gt;cards;&lt;/P&gt;&lt;P&gt;1 a&lt;/P&gt;&lt;P&gt;2 b&lt;/P&gt;&lt;P&gt;3 c&lt;/P&gt;&lt;P&gt;4 d&lt;/P&gt;&lt;P&gt;5 e&lt;/P&gt;&lt;P&gt;;&lt;/P&gt;&lt;P&gt;run;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Data Tab2;&lt;/P&gt;&lt;P&gt;input y $;&lt;/P&gt;&lt;P&gt;hh&lt;/P&gt;&lt;P&gt;ii&lt;/P&gt;&lt;P&gt;jj&lt;/P&gt;&lt;P&gt;uu&lt;/P&gt;&lt;P&gt;kk&lt;/P&gt;&lt;P&gt;;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Outuput -&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Tab3 -&lt;/P&gt;&lt;P&gt;id x y&lt;/P&gt;&lt;P&gt;1 a hh&lt;/P&gt;&lt;P&gt;2 b ii&lt;/P&gt;&lt;P&gt;3 c jj&lt;/P&gt;&lt;P&gt;4 d uu&lt;/P&gt;&lt;P&gt;5 e kk&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;It can be done by using multiple set statement. But, how can we do it by using proc sql?&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 06 Feb 2015 10:24:52 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156679#M30597</guid>
      <dc:creator>nikunjgattani</dc:creator>
      <dc:date>2015-02-06T10:24:52Z</dc:date>
    </item>
    <item>
      <title>Re: How to apply multiple set property using proc sql?</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156680#M30598</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Firstly I don't recommend merging data based on an adhoc position in a dataset.&amp;nbsp; If the sequence changes, say extra rows added, or sorted differently you will end up with different outcome, hence this kind of merge is dangerous. &lt;/P&gt;&lt;P&gt;If however you are set on this course of action:&lt;/P&gt;&lt;P&gt;proc sql;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; create table WANT as&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; select&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; A.ID,&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; A.X,&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; B.Y&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; from&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; (select *,MONOTONIC() as _N from DS1) A&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; left join&amp;nbsp; (select *,MONOTONIC() as _N from DS2) B&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; on&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; A._N=B._N;&lt;/P&gt;&lt;P&gt;quit;&lt;/P&gt;&lt;P&gt;Note the monotonic function is currently unsupported and may return un-expected results.&amp;nbsp; The underlying fact about merging is that there should be a logical set of matching identifier variables in each table to match against.&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 06 Feb 2015 10:48:25 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156680#M30598</guid>
      <dc:creator>RW9</dc:creator>
      <dc:date>2015-02-06T10:48:25Z</dc:date>
    </item>
    <item>
      <title>Re: How to apply multiple set property using proc sql?</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156681#M30599</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;You need to create a index variable ID in Tab1 as in Tab2;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Data Tab1;&lt;/P&gt;&lt;P&gt;input id x $;&lt;/P&gt;&lt;P&gt;cards;&lt;/P&gt;&lt;P&gt;1 a&lt;/P&gt;&lt;P&gt;2 b&lt;/P&gt;&lt;P&gt;3 c&lt;/P&gt;&lt;P&gt;4 d&lt;/P&gt;&lt;P&gt;5 e&lt;/P&gt;&lt;P&gt;;&lt;/P&gt;&lt;P&gt;run;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Data Tab2;&lt;/P&gt;&lt;P&gt;input y $;&lt;/P&gt;&lt;P&gt;cards;&lt;/P&gt;&lt;P&gt;hh&lt;/P&gt;&lt;P&gt;ii&lt;/P&gt;&lt;P&gt;jj&lt;/P&gt;&lt;P&gt;uu&lt;/P&gt;&lt;P&gt;kk&lt;/P&gt;&lt;P&gt;;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;data tab2;&lt;/P&gt;&lt;P&gt; set tab2;&lt;/P&gt;&lt;P&gt; id+1;&lt;/P&gt;&lt;P&gt;run;&lt;/P&gt;&lt;P&gt;proc sql;&lt;/P&gt;&lt;P&gt; create table want as&lt;/P&gt;&lt;P&gt;&amp;nbsp; select * &lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp; from tab1 natural join tab2 ;&lt;/P&gt;&lt;P&gt;quit;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Xia Keshan&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 06 Feb 2015 10:51:10 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156681#M30599</guid>
      <dc:creator>Ksharp</dc:creator>
      <dc:date>2015-02-06T10:51:10Z</dc:date>
    </item>
    <item>
      <title>Re: How to apply multiple set property using proc sql?</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156682#M30600</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Use the right tool, which in this case is the data step with a merge; no need for SQL.&lt;/P&gt;&lt;P&gt;Of course you can try to put the screw into the wood by detonating a pound of dynamite on top of it, but a screwdriver is the better option.&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 06 Feb 2015 13:04:02 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156682#M30600</guid>
      <dc:creator>Kurt_Bremser</dc:creator>
      <dc:date>2015-02-06T13:04:02Z</dc:date>
    </item>
    <item>
      <title>Re: How to apply multiple set property using proc sql?</title>
      <link>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156683#M30601</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;To re-write an old favourite - select needle from haystack&lt;/P&gt;&lt;P&gt;How about - insert screw into wood&lt;/P&gt;&lt;P&gt;What could be simpler?&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 06 Feb 2015 14:10:45 GMT</pubDate>
      <guid>https://communities.sas.com/t5/SAS-Programming/How-to-apply-multiple-set-property-using-proc-sql/m-p/156683#M30601</guid>
      <dc:creator>RW9</dc:creator>
      <dc:date>2015-02-06T14:10:45Z</dc:date>
    </item>